Check Ground Continuity Of Black Cable; Check Continuity Of Yellow Cable - Malaguti MADISON 3 125 cc Workshop Manual

Electrical system
Table of Contents

Advertisement

B
CHAPTER

7.4 Check ground continuity of black cable

- Connect Tester ( ) as follows:
- Terminal (+) of tester
- Terminal (-) of tester
- No continuity: black cable interrupted.
- Repair by providing a jumper between the black cable and a grounded point of the chassis.
+12 V WITH KEY ON
F. 51

7.5 Check continuity of yellow cable

- Connect Tester ( ) to yellow cable leading from thermal switch to radiator fan connector, as follows:
- Terminal (+) of tester
- Terminal (+) of tester
- No continuity: the relative yellow cable is interrupted.
- Repair, see "Wiring Diagram".
- Continuity: yellow cable leading from fuse holder to thermal switch is interrupted.
- Repair; see "Wiring Diagram".