5.7

TEACH mode

Fig. 17
Menu structure for TEACH mode
The TEACH mode can be used to teach-in the switching points of the distance monitoring function for
the threshold value comparator switching function. The binary signals Out A and Out B can be provided
with two values that are independent of one another.
Note
The procedure for teaching the binary signals Out A (A pushbutton) and Out B (B push­
button) is the same. The procedure is described below based on the binary signal Out A.
1. Set the desired sensing distance between the object and measuring nozzle.
2. First press the A pushbutton and then the Edit button as well.
è [Out A] and [TeachIn] flash. The value is transferred as the switching point.
è If [Lock] flashes (security lock active): The value is stored in the buffer.
If the security lock is active [Lock]:
3. Set the security code by using the A/B pushbuttons.
4. Press the Edit button.
è [Out A] and [TeachIn] flash. The value that is stored in the buffer in step 2 is transferred as the
switching point.
è SOPA switches to RUN mode.