Switch On Sensor (Run Mode); Switchover Of Measured Value Indicator; Displaying Parameters (Show Mode); Enter The Security Code (Edit Mode) - Festo SFAH Instructions & Operating

Flow sensor
Hide thumbs Also See for SFAH:
Table of Contents

Advertisement

Example for LCD display
Main display
Lower display
[16]
[Filt] / [MSEC]
[L.Min]
[FLOW Unit]
[0°C]
[REF] / [Cond]
[Air]
[GAS]
[1->2]
[FLOW] / [Path]
[ON]
[Z.Adj]
[Unit]
[Sub.d]
[40]
[Eco] / [SEC]
[PNP]
[bin] / [Out]
[Flow]
[bin] / [Pin4]
[bin]
[FLOW] / [Pin2]
[OFF]
[Code]
[OFF]
[MASt]
Tab. 15
8.2

Switch on sensor (RUN mode)

Switch on the operating voltage.
Ä Current measured value is displayed. The sensor is in the basic status
(RUN mode).
The basic static can be established using the following actions:
Press the Edit button for 3 seconds
Expiration of a monitoring time (timeout)
8.3

Switchover of measured value indicator

Switchover to flow rate measurement: press A pushbutton.
Switchover to volume measurement: press B pushbutton.
8.4

Displaying parameters (SHOW mode)

Requirement: The sensor is ready for operation (RUN mode).
Switching output OutA or volume pulse output
1. Press the A pushbutton twice.
Ä The first parameter set is displayed. [Fctn] flashes for OutA or [SP] flashes
for "Puls".
2. To display each of the following parameters, press the A pushbutton
(è Fig.10).
The averaged flow rate value [AVER] is displayed at the end.
Switching output OutB or analogue output Anlg
1. Press B pushbutton
Ä The first parameter set is displayed. [Fctn] flashes for OutB or [Out]
flashes for Anlg.
2. To display each of the following parameters, press the A pushbutton
(è Fig.10).
For bidirectional product variant SFAH-...B-..., the flow direction [Path] is dis-
played at the end.
Meaning
Value of the filter time constant for the measure-
ment signal
Display unit for flow rate measurement
Reference standard for gas volume
Selection of the operating medium
Selection of the flow direction from Port 1 to 2 or
vice versa (only for bidirectionally calibrated
product variant)
Offset synchronisation for display, switching and
analogue output
Settings of the lower display in RUN mode: selec-
ted unit or switching point of OutA or bar graph
or gas or flow direction
Economy mode: period after which the display
background lighting is switched off
Shift of the switching outputs (binary) between
PNP and NPN
Shift of binary switching output or pulse output.
Pin 4 with M8 variant, pin 2 with L1 variant
Shift of binary switching output or analogue out-
put to pin 2 in M8 variant, pin 3 with L1 variant
Activation and determination of the security
code
Activation of the IO-Link® master function for
replication of parameters
Fig. 10 Measured value indicator (RUN mode)
Legend
Meaning
Edit button
A or B pushbutton
Double-press the A or B pushbutton
1)
Not for flow unit G.Min
2)
Only for bidirectional product variant
3)
Selectable values: 256, 512, 1024 ms
Tab. 16 Legend for measured value indicator (RUN mode)
8.5

Enter the security code (EDIT mode)

Requirement: The sensor is ready for operation (RUN mode).
1. Press the Edit button.
Ä The EDIT mode is active. If the security code is activated, the parameter
entry option is blocked: [Lock] flashes.
2. Enter the set security code using the A or B pushbutton.
3. Press the Edit button briefly.
Ä [OutA] flashes. The parameter entry option is unblocked.
8.6
Configuring switching output (EDIT mode)
The process is the same for configuring the switching outputs for [OutA] and
[OutB.] In the following, the process is described using the switching output OutA.
Menu structure è 8.12 Menu structure (EDIT mode).
Requirement: The sensor is ready for operation (RUN mode).
1. Press the Edit button briefly.
Ä [Edit] appears. [OutA] flashes.
2. Press the Edit button briefly.
Ä [Fctn] flashes.
3. Select switching function _I¯ or _I¯I_ or d_I¯I_ with the A or B button.
4. Press the Edit button briefly.
Ä The set value is saved. The next adjustable parameter is shown.
5. Set the parameter with A or B pushbutton.
6. Repeat steps 4 and 5 until all parameters are set (switching functions
è 5.2.2.1 Switching functions).