C.2 Timer - Photon Focus MV3-D640I-M01-144-G2-12 User Manual

Mv3-d640i-m01-144-g2 series cmos camera with gigabit ethernet interface
Table of Contents

Advertisement

3.
The TriggerSource of the ExposureStart trigger must be set to Line0.
4.
The TriggerActivation of the ExposureStart trigger must be set to RisingEdge.
5.
The TriggerSource of the ExposureEnd trigger must be set to Line0.
6.
The TriggerActivation of the ExposureEnd trigger must be set to FallingEdge.
7.
TriggerDelay and TriggerDivider of the ExposureStart and ExposureEnd trigger must be set
accordingly.
8.
The required image Width and Height must be set.
9.
The required PixelFormat must be set.
10. AcquisitionMode must be set to Continuous.
11. The software command AcquisitionStart() must be applied.

C.2 Timer

There are four general purpose timers available. The following sections show some use cases,
how the timers can be used.
C.2.1 Strobe Signal Output
The timer can be used to generate a pulse with a certain width on the LineOut output together
with every exposure cycle in order to control an external light. The following procedure shows,
how to configure one of the timer for this purposes:
1.
Select one of the four available timers by setting of the TimerSelector to Timer0, Timer1,
Timer2 or Timer3.
2.
Select the timer trigger source. Set TimerTriggerSource to ExposureStart.
3.
Parameter TimerTriggerActivation can be ignored. This configuration is only necessary,
when Line0 input is selected as a trigger source.
4.
Configure the necessary TimerDuration value and the TimerDelay value.
At this stage, the configured timer generates a pulse of a certain width and after a certain
delay every time, when a new exposure cycle starts, which is indicated by the internally
available TimerActive status. This signal must be connected to the camera LineOut output,
which can be done in the DigitalIOControl section:
1.
Set the LineSelector to LineOut0.
2.
Set the LineSource of this output to the corresponding timer acitve signal: Timer0Active,
Timer1Active, Timer2Active or Timer3Active.
3.
Set the polarity of this output accordingly with the parameter LineInverter.
C.3 Counter
There are four general purpose counters available, which can be used to count any events in
the camera. The following sections show some use cases, how the counters can be used. There
are some examples of simple counter configurations as well as some more sophisticated
settings.
MAN076 09/2017 V1.0
C.2 Timer
117 of 121

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mv3-d640i-m01-144-cl

Table of Contents