Photon Focus MV3-D640I-M01-144-G2-12 User Manual page 119

Mv3-d640i-m01-144-g2 series cmos camera with gigabit ethernet interface
Table of Contents

Advertisement

1.
Select one of the four available counters by setting of the CounterSelector to Counter0,
Counter1, Counter2 or Counter3.
2.
Set the corresponding CounterEventSource to MissedAcqStartTrigger,
MissedFrameStartTrigger, MissedFrameBurstStartTrigger, MissedExposureStartTrigger or
MissedTrigger.
3.
Parameter TimerTriggerActivation can be ignored. This configuration is only necessary,
when Line0 input is selected as a trigger source.
4.
All other counter parameter must be left in default state (Both the CounterResetSource and
CounterTriggerSource must be set to Off)
5.
The counter needs to be reset (see C.3.1).
MAN076 09/2017 V1.0