Technical Information
6. Remove the adjustment slide switch frame. See Section 5.7.
7. Remove the adjustment lever retaining screws.
8. Remove the adjustment lever.
9. Remove the cover retaining screws (Figure 5-50, Item 4).
10. Remove the cover.
Note:
Mark the polarity of the plug (Figure 5-50, Item 1) connected to the electronic.
Figure 5-50: Accessing the Grinder for Complete Removal
11. Disconnect the plug from the electronic.
12. Lift the grinder upwards from the dampers (see Figure 5-51, Item 2).
Figure 5-51: Grinder Coupling
Note:
When re-installing the grinder, the dampers should be seated in the
mounting plate and motor holder to ensure that the grinder coupling is set to
an optimal position and grinder noise is kept to a minimum.
CVA 610/CVA 615 Coffee Systems