CVA 610/CVA 615 Coffee Systems
7. Grasp the brew unit handle and pull the brew unit out until the connection socket
on the brew unit (Figure 5-20, Item 1) unsnaps from the brew unit and remains
inside the appliance attached to the water nozzle.
8. Remove the brew unit; see Section 5.26.
9. Slide the connection socket down to remove it from the appliance.
10. Re-install the connection socket on the brew unit.
11. Carefully inspect the drive for defects.
12. Test the home and brewing position switches for proper operation.
Figure 5-20: Brew Unit
Technical Information
53