CVA 610/CVA 615 Coffee Systems
Figure 5-29: Brew Unit Output and Handle
5.36
Brew Unit Funnel Removal
1. Remove the brew unit; see Section 5.26.
2. Press the funnel locking tab (Figure 5-30, Item 1), so that the funnel is no longer
raised.
3. Lever the funnel up and out of its holder (Figure 5-31).
Note:
When re-installing the funnel, ensure that the spring (Figure 5-31, Item 1) is seated
correctly.
Figure 5-30: Brew Unit Funnel Lock
Technical Information