Figure 4-10: Water Level Switch
The actuating magnet for the water level switch is located within the float. The float is
then installed into the water tank, as shown in Figure 4-11, Item 1.
Figure 4-11: Water Level Float Switch
With the water tank installed and containing at least 900 to 1000 milliliters (30 to 33
ounces) of water, the water level switch activates and its contacts close.
When the water quantity drops below the minimum level (800 milliliters or 27
ounces), the water level switch contacts open. After the switch opens, the water