Figure 5-37: Grinder Retaining Screws - Miele CVA 610 Technical Information

Coffee systems
Table of Contents

Advertisement

CVA 610/CVA 615 Coffee Systems

Figure 5-37: Grinder Retaining Screws

Figure 5-38: Grinder Retaining Nuts
20. Remove the knobs from the grinder slide controls.
21. Remove the adjustment slide switch frame (Section 5.7).
22. Position the grinder as necessary to access the drive cover and drive unit
retaining screws. Refer to Figure 5-36 for the location of the screws.
23. Remove the two upper front plate assembly retaining screws as shown in Figure
5-39.
24. Remove all remaining screws from the front plate assembly. Lift upward on the
front plate assembly to access the screws near the bottom of the plate. Use
Figure 5-36 to locate all screws.