Overflow Switch Actuator Float Removal - Miele CVA 610 Technical Information

Coffee systems
Table of Contents

Advertisement

CVA 610/CVA 615 Coffee Systems
5.11

Overflow Switch Actuator Float Removal

1. Remove the lid (Section 5.1), interference suppression filter (Section 5.2) and
rear panel (Section 5.6).
2. Remove the base plate; see Section 5.9.
3. Remove the float. See Figure 5-8, Item 1.
Note:
Ensure that the float is re-installed in the same direction as when it was
removed.
Figure 5-8: Overflow Switch Actuator Float
5.12
Overflow Switch (B8/3) Removal
1. Remove the lid (Section 5.1), interference suppression filter (Section 5.2) and
rear panel (Section 5.6).
2. Remove the screw securing the overflow switch (Figure 5-9, Item 1).
3. Remove the overflow switch, and disconnect its electrical connections.
Technical Information
1 Overflow switch float
2 Magnet inside float
43