Ground Coffee Dispensing - Miele CVA 610 Technical Information

Coffee systems
Table of Contents

Advertisement

CVA 610/CVA 615 Coffee Systems
4.11

Ground Coffee Dispensing

By adjusting the dispenser lever (Figure 4-14, Item 1), the position of the dispensing
switch (Figure 4-14, Item 2) is modified. The change results in a change in volume of
the dispenser container, so the quantity of ground coffee changes. Each position
along the setting alters the coffee quantity by about 0.5 grams.
The grinder fills the dispenser container with ground coffee. When the dispenser
container is full, the dispenser switch is activated and the grinder motor is switched
off.
Figure 4-14: Coffee-Dispensing Components
The dispensing solenoid is activated twice by the electronic. During the initial
activation the ground coffee drops into the brew unit. The second activation is to
ensure that no loose grounds block the channel as the wiper passes and loosens
any ground coffee residues.
If the dispenser container is not filled (i.e. no coffee beans) the dispenser switch is
not activated and the "Fill coffee beans" message is displayed.
Figure 4-15: Dispensing Lever
Technical Information
27
1 Dispenser level
2 Dispensing switch
3 Dispensing switch catch
4 Dispensing coil catch
5 Dispensing coil (1L1)
6 Spring
7 Actuator
8 Bolt
9 Dispenser flap
10 Wiper