5.5
Tuning time
6
TERMINAL UNIT (IB-583, OPTION)
6.1
Display
6.2
Memory
6.3
Keyboard
7
INTERFACE
7.1
Input data sentences
Ship's Position (L/L)
Time
7.2
LAN
8
POWER SUPPLY
8.1
Transceiver/control unit
FS-2575
FS-5075
8.2
Terminal unit (IB-583)
8.3
Printer (PP-510, option) 24 VDC: 1.5 A
8.4
AC/DC power supply unit 100/110/120/200/220/240VAC, 1 phase, 50/60 Hz
9
ENVIRONMENTAL CONDITION
9.1
Ambient temperature
Antenna coupler
Indoor units
9.2
Relative humidity
9.3
Degree of protection
Antenna coupler
Transceiver/terminal unit IP22 (bulkhead mount only)
Control unit
9.4
Vibration
10
COATING COLOR
10.1 Transceiver/control unit N2.5
10.2 Antenna coupler
Within 15 seconds
10.4" color TFT LCD, 640 x 480 dots
Flash ROM: 1 MB, S-RAM: 256 KB
IBM PS/2
IEC 61162-1
GGA, GLL, GNS, RMC
ZDA
Ethernet 10Base-T/100Base-TX
24 VDC: 5A (RX), 40A max. (TX)
24 VDC: 5A (RX), 60A max. (TX)
24 VDC: 0.6 A
-25°C to +55°C
-15°C to +55°C
93% or less at 40°C
IP56
IP22
IEC60945 Ed.4
N9.5 (white)
SP - 3
FS-2575/5075
E5678S01A-M