NOTE:Above parameters are in 24V system at 25 º C, please double the
values in 48V system
Bypass indicator:indicator bypass input
LED Status
Green ON
Green OFF
NOTE: Only when bypass is in priority mode, and the inverter is
connected and in normal state, bypass can function the load short
circuit, otherwise, the inverter will be damaged!
2) When the bypass voltage is lower than 176Vac or higher than
264Vac, the bypass output will perform a protective function, and
switch to the inverter output or stop the output. When the bypass
voltage recovers the range from 190Vac to 240Vac, the output will
be recovered.
Alarms
Alarms
Buzzer Sounds
NOTE: The buzzer stops after 20S.
Flashing
Overload or Short circuit, No Output
Over or Low input voltage, No Output
Over temperature, No Output
Inverter Fault, No Output
Flashing
Red ON
Green ON
OFF
Input normal
Input no voltage
Status
9
Output voltage abnormal
Inverter output normal
Bypass output or inverter
output is OFF(normal OFF)
Bypass