Epever SHI2000-22-G User Manual page 10

Shi-g series pure sine wave inverter
Table of Contents

Advertisement

Schematic diagram of the sysem connection
Input Wire(Distance<3m)
2
50mm
(SHI3000-22-G)
2
25mm
(SHI3000-42-G)
2
35mm
(SHI2000-22-G)
2
16mm
(SHI2000-42-G)
DC Breaker
DC 150A (SHI3000-22-G)
DC 75A (SHI3000-42-G)
DC 100A (SHI2000-22-G)
DC 50A (SHI2000-42-G)
Order of connection:
1. When the inverter is OFF, connect the battery and load according to the above picture.
2. After the connection of the bypass is completed, turn on the external bypass switch. If the indicator
is normally lit and green, it means that the connection is normal.
3. Turn on the inverter first. Two seconds later, turn on the bypass switch.
NOTE: When dismantling the inverter, switch off the loads first, then turn off the mains supply switch,
and then turn off the inverter, and finally disconnect the output and input connection lines finally.
AC Breaker
AC 15A (SHI3000-22-G)
AC 15A (SHI3000-42-G)
AC 10A (SHI2000-22-G)
AC 10A (SHI2000-42-G)
AC Breaker
AC 15A (SHI3000-22-G)
AC 15A (SHI3000-42-G)
AC 10A (SHI2000-22-G)
AC 10A (SHI2000-42-G)
6
Mains and AC power
supply(220/230VAC)
Output Wire(Distance<50m)
2
6mm
(SHI3000-22-G)
2
6mm
(SHI3000-42-G)
2
4mm
(SHI2000-22-G)
2
4mm
(SHI2000-42-G)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Shi3000-22-gShi3000-42-gShi2000-42-g

Table of Contents