Connection Of 2.4 Ghz Portable Stations - Panasonic KX-TDA600 Installation Manual

Hybrid ip-pbx
Hide thumbs Also See for KX-TDA600:
Table of Contents

Advertisement

2.11 Connection of 2.4 GHz Portable Stations

2.11 Connection of 2.4 GHz Portable Stations
2.11.1 Overview
The following equipment is required to connect the wireless system:
CS: Cell Station (KX-TDA0142/KX-TDA0141)
KX-TDA0142 Using a CSIF Card
This unit determines the area covered by the wireless system. Up to 3 calls can be made at the same
time through each CS.
CSIF4 (KX-TDA0143)
One CSIF4 card supports up to 4 Cell Stations.
CSIF8 (KX-TDA0144)
One CSIF8 card supports up to 8 Cell Stations.
KX-TDA0141 Using a DHLC/DLC Card
This unit determines the area covered by the wireless system. Up to 2 calls can be made at the same
time through each CS.
PS: 2.4 GHz Portable Station (KX-TD7680/KX-TD7690)
The Hybrid IP-PBX can support up to 256 PSs. If an EMEC card is installed in the Hybrid IP-PBX, up to 512
PSs can be supported. For more details about the PS, refer to the PS Operating Instructions.
CAUTION
The CS should be kept free of dust, moisture, high temperature (more than 40
(less than 0
The CS should not be placed outdoors (use indoors).
The CS should not be placed near high-voltage equipment.
The CS should not be placed on a metal object.
Systems using 2.4 GHz ISM (Industrial, Scientific and Medical) band may interfere with the KX-
TDA wireless system. Examples of such systems are cordless telephones, wireless LAN, Home
RF, microwave ovens and other ISM devices. These systems may cause minor noise.
Keeping some distance between the equipment listed below may prevent interference. (The
distance may vary depending on the environment.)
Equipment
CS and office equipment such as a computer, telex, fax
machine, etc.
CS and PS
Each PS
Hybrid IP-PBX and CS
CS and CS
226
Installation Manual
), and vibration, and should not be exposed to direct sunlight.
˚C
WWW.ERTEBATGROUP.COM
WWW.ERTEBATGROUP.COM
), low temperature
˚C
Distance
More than 2 m
More than 1 m
More than 0.5 m
More than 2 m
More than 15 m