GE C30 Instruction Manual page 330

Controller system ur series
Hide thumbs Also See for C30:
Table of Contents

Advertisement

B.4 MEMORY MAPPING
Table B–9: MODBUS MEMORY MAP (Sheet 19 of 46)
ADDR
REGISTER NAME
74F8
...Repeated for DCmA Inputs 22
7510
...Repeated for DCmA Inputs 23
7528
...Repeated for DCmA Inputs 24
Disconnect (Breaker) Switch (Read/Write Settings) (24 modules)
7540
Disconnect Switch 1 Function
B
7541
Disconnect Switch 1 Name
7544
Disconnect Switch 1 Mode
7545
Disconnect Switch 1 Open
7546
Disconnect Switch 1 Block Open
7547
Disconnect Switch 1 Close
7548
Disconnect Switch 1 Block Close
7549
Disconnect Switch 1 Phase A / Three-pole Closed
754A
Disconnect Switch 1 Phase A / Three-pole Opened
754B
Disconnect Switch 1 Phase B Closed
754C
Disconnect Switch 1 Phase B Opened
754D
Disconnect Switch 1 Phase C Closed
754E
Disconnect Switch 1 Phase C Opened
754F
Disconnect Switch 1 Operate Time
7550
Disconnect Switch 1 Alarm Delay
7552
Disconnect Switch 1 Events
7553
Reserved (2 items)
7555
...Repeated for Disconnect Switch 2
756A
...Repeated for Disconnect Switch 3
757F
...Repeated for Disconnect Switch 4
7594
...Repeated for Disconnect Switch 5
75A9
...Repeated for Disconnect Switch 6
75BE
...Repeated for Disconnect Switch 7
75D3
...Repeated for Disconnect Switch 8
75E8
...Repeated for Disconnect Switch 9
75FD
...Repeated for Disconnect Switch 10
7612
...Repeated for Disconnect Switch 11
7627
...Repeated for Disconnect Switch 12
763C
...Repeated for Disconnect Switch 13
7651
...Repeated for Disconnect Switch 14
7666
...Repeated for Disconnect Switch 15
767B
...Repeated for Disconnect Switch 16
7690
...Repeated for Disconnect Switch 17
76A5
...Repeated for Disconnect Switch 18
76BA
...Repeated for Disconnect Switch 19
76CF
...Repeated for Disconnect Switch 20
76E4
...Repeated for Disconnect Switch 21
76F9
...Repeated for Disconnect Switch 22
770E
...Repeated for Disconnect Switch 23
7723
...Repeated for Disconnect Switch 24
Ohm Inputs (Read/Write Setting) (2 modules)
7840
Ohm Inputs 1 Function
7841
Ohm Inputs 1 ID
7847
Ohm Inputs 1 Reserved (9 items)
7850
...Repeated for Ohm Inputs 2
User Programmable Pushbuttons (Read/Write Setting) (16 modules)
7B60
User Programmable Pushbutton 1 Function
7B61
User Programmable Pushbutton 1 Top Line
7B6B
User Programmable Pushbutton 1 On Text
7B75
User Programmable Pushbutton 1 Off Text
B-26
RANGE
UNITS
0 to 1
---
0 to 1
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 2
0 to 1000000
0 to 1
---
0 to 1
---
0 to 65535
0 to 2
---
---
---
C30 Controller System
APPENDIX B
STEP
FORMAT
---
1
F102
0 (Disabled)
---
---
F206
---
1
F157
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
s
0.001
F001
s
0.001
F003
---
1
F102
0 (Disabled)
---
---
F001
---
1
F102
0 (Disabled)
---
---
F205
---
1
F001
---
1
F137
0 (Disabled)
---
---
F202
---
---
F202
---
---
F202
DEFAULT
"SW 1"
0 (3-Pole)
0
0
0
0
0
0
0
0
0
0
70
0
0
"Ohm Ip 1 "
0
(none)
(none)
(none)
GE Multilin

Advertisement

Table of Contents
loading