Download  Print this page

Force Contact Outputs - GE C30 Instruction Manual

Controller system ur series.
Hide thumbs
   
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
Table of Contents
441

Advertisement

Table of Contents
5.9 TESTING

PATH: SETTINGS
TESTING
 FORCE CONTACT
 OUTPUTS
The relay contact outputs can be pre-programmed to respond to the test mode.
If set to "Disabled", the contact output remains fully operational. If operates when its control operand is logic 1 and will
resets when its control operand is logic 0. If set to "Energized", the output will close and remain closed for the entire dura-
tion of the test mode, regardless of the status of the operand configured to control the output contact. If set to "De-ener-
gized", the output will open and remain opened for the entire duration of the test mode regardless of the status of the
operand configured to control the output contact. If set to "Freeze", the output retains its position from before entering the
test mode, regardless of the status of the operand configured to control the output contact.
These settings are applied two ways. First, external circuits may be tested by energizing or de-energizing contacts. Sec-
ond, by controlling the output contact state, relay logic may be tested and undesirable effects on external circuits avoided.
Example 1: Initiating test mode through user-programmable pushbutton 1
5
For example, the test mode can be initiated from user-programmable pushbutton 1. The pushbutton will be programmed as
"Latched" (pushbutton pressed to initiate the test, and pressed again to terminate the test). During the test, digital input 1
should remain operational, digital inputs 2 and 3 should open, and digital input 4 should close. Also, contact output 1 should
freeze, contact output 2 should open, contact output 3 should close, and contact output 4 should remain fully operational.
The required settings are shown below.
To enable user-programmable pushbutton 1 to initiate the test mode, make the following changes in the
TESTING
TEST MODE
Make the following changes to configure the contact inputs and outputs. In the
and
INPUTS

FORCE CONTACT OUTPUTS

"Disabled",
FORCE Cont Ip 1:
"Freeze",
FORCE Cont Op 1:
and
FORCE Cont Op 4:
Example 2: Initiating a test from user-programmable pushbutton 1 or through remote input 1
In this example, the test can be initiated locally from user-programmable pushbutton 1 or remotely through remote input 1.
Both the pushbutton and the remote input will be programmed as "Latched". Write the following FlexLogic™ equation:
Set the user-programmable pushbutton as latching by changing
PUSHBUTTONS
USER PUSHBUTTON 1
input 1 to initiate the Test mode, make the following changes in the
TEST MODE FUNCTION:
5-130

FORCE CONTACT OUTPUTS
FORCE Cont Op 1
:Disabled
FORCE Cont Op 2
MESSAGE
:Disabled
FORCE Cont Op xx
MESSAGE
:Disabled
menu:
TEST MODE FUNCTION:
menus, set:
"Open",
FORCE Cont Ip 2:
"De-energized",
FORCE Cont Op 2:
"Disabled"
PUSHBUTTON 1 FUNCTION
"Enabled" and
TEST MODE INITIATE:
C30 Controller System
Range: Disabled, Energized, De-energized, Freeze
Range: Disabled, Energized, De-energized, Freeze
Range: Disabled, Energized, De-energized, Freeze
"Enabled" and
TEST MODE INITIATE:
SETTINGS
"Open", and
FORCE Cont Ip 3:
FORCE Cont Op 3:
SETTINGS
PRODUCT SETUP
to "Latched". To enable either pushbutton 1 or remote

SETTINGS
"
"
VO1
5 SETTINGS
5.9.3 FORCE CONTACT OUTPUTS
SETTINGS
"
"
PUSHBUTTON 1 ON


TESTING
FORCE CONTACT
"Closed"
FORCE Cont Ip 4:
"Energized",

USER-PROGRAMMABLE
menu:
TESTING
TEST MODE

GE Multilin