GE C30 Instruction Manual page 326

Controller system ur series
Hide thumbs Also See for C30:
Table of Contents

Advertisement

B.4 MEMORY MAPPING
Table B–9: MODBUS MEMORY MAP (Sheet 15 of 46)
ADDR
REGISTER NAME
User Programmable Self Tests (Read/Write Setting)
4441
User Programmable Detect Ring Break Function
4442
User Programmable Direct Device Off Function
4443
User Programmable Remote Device Off Function
4444
User Programmable Primary Ethernet Fail Function
B
4445
User Programmable Secondary Ethernet Fail Function
4446
User Programmable Battery Fail Function
4447
User Programmable SNTP Fail Function
4448
User Programmable IRIG-B Fail Function
4449
User Programmable Ethernet Switch Fail Function
444A
Process Bus Failure Operand
Breaker Control (Read/Write Settings)
4700
Breaker 1 Function
4701
Breaker 1 Name
4704
Breaker 1 Mode
4705
Breaker 1 Open
4706
Breaker 1 Close
4707
Breaker 1 Phase A / Three-pole Closed
4708
Breaker 1 Phase B Closed
4709
Breaker 1 Phase C Closed
470A
Breaker 1 External Alarm
470B
Breaker 1 Alarm Delay
470D
Breaker 1 Pushbutton Control
470E
Breaker 1 Manual Close Recall Time
4710
Breaker 1 Out of Service
4711
Breaker 1 Block Open
4712
Breaker 1 Block Close
4713
Breaker 1 Phase A / Three-pole Opened
4714
Breaker 1 Phase B Opened
4715
Breaker 1 Phase C Opened
4716
Breaker 1 Operate Time
4717
Breaker 1 Events
4718
Reserved
4719
...Repeated for Breaker 2
Modbus User Map (Read/Write Setting)
4A00
Modbus Address Settings for User Map (256 items)
User Displays Settings (Read/Write Setting) (16 modules)
4C00
User-Definable Display 1 Top Line Text
4C0A
User-Definable Display 1 Bottom Line Text
4C14
Modbus Addresses of Display 1 Items (5 items)
4C19
Reserved (7 items)
4C20
...Repeated for User-Definable Display 2
4C40
...Repeated for User-Definable Display 3
4C60
...Repeated for User-Definable Display 4
4C80
...Repeated for User-Definable Display 5
4CA0
...Repeated for User-Definable Display 6
4CC0
...Repeated for User-Definable Display 7
4CE0
...Repeated for User-Definable Display 8
4D00
...Repeated for User-Definable Display 9
4D20
...Repeated for User-Definable Display 10
4D40
...Repeated for User-Definable Display 11
4D60
...Repeated for User-Definable Display 12
4D80
...Repeated for User-Definable Display 13
4DA0
...Repeated for User-Definable Display 14
B-22
RANGE
UNITS
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
0 to 1
0 to 65535
0 to 1
---
0 to 1
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 1000000
0 to 1
0 to 1000000
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 2
0 to 1
0 to 65535
0 to 65535
---
---
0 to 65535
---
C30 Controller System
APPENDIX B
STEP
FORMAT
---
1
F102
---
1
F102
---
1
F102
---
1
F102
0 (Disabled)
---
1
F102
0 (Disabled)
---
1
F102
---
1
F102
---
1
F102
---
1
F102
---
1
F300
---
1
F102
0 (Disabled)
---
---
F206
---
1
F157
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
s
0.001
F003
---
1
F102
0 (Disabled)
s
0.001
F003
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
s
0.001
F001
---
1
F102
0 (Disabled)
s
1
F001
---
1
F001
---
---
F202
---
---
F202
---
1
F001
---
---
F001
DEFAULT
1 (Enabled)
1 (Enabled)
1 (Enabled)
1 (Enabled)
1 (Enabled)
1 (Enabled)
1 (Enabled)
0
"Bkr 1"
0 (3-Pole)
0
0
0
0
0
0
0
0
0
0
0
0
0
0
70
0
0
" "
""
0
0
GE Multilin

Advertisement

Table of Contents
loading

Table of Contents