Table 17 Input Channels - HP 54620A User's And Service Manual

Logic analyzer
Hide thumbs Also See for 54620A:
Table of Contents

Advertisement

Table 17
Input channels
Number of Channels
Channel input cable
Input R&C
Maximum Input
Dynamic range
Minimum input
Minimum Input Voltage Overdrive
Threshold Setting
Threshold Range
Threshold Accuracy
Preset threshold levels
Channel-to-Channel Skew
1
Performance specification, tested by threshold test. See Chapter 5, "Testing, Adjusting, and Troubleshooting
the Analyzer."
16, numbered 0-15.
HP 54620-61801 with channels grouped in
two sets of 8. Instrument is compatible with
16-channel HP 1650-61607 cable and
accessories.
~100 k Ω and 8 pF.
± 40 Volts peak.
± 10V about threshold.
500 mV peak-to-peak about threshold.
To meet timing accuracy, the threshold
value must be within 20% of the 50% value
of the input signal.
Threshold levels can be assigned to the
input channels in groups of 8 channels (0-7
and 8-15) and external trigger.
± 6.0 Volts.
1
± (3% of setting ± 100 mV).
TTL = 1.5 V.
CMOS = 2.5 V.
ECL = –1.3 V.
2.0 ns typical.
3.0 ns maximum.
Performance Characteristics