All optical power numbers are listed as dBm averages.
k
Typical distance. The maximum segment length is greatly dependent on factors such as fiber quality, and the number of patches and splices. Consult a Siemens
sales associate when determining maximum segment distances.
l
Meets Criteria A for ESD testing. No packet loss occurs during ESD discharges directly to the transceiver. Normal operation/function will resume following
testing.
m
The SFP transceiver meets the requirements of Criteria A, as defined by IEC 61000-6-2 (Generic Industrial) and EN50121-3-2 (Wayside Rail EMC)
n
Meets Criteria B for ESD testing. Some packet loss occurs during ESD discharges directly to the transceiver. Normal operation/function will resume following
testing.
o
The SFP transceiver meets the requirements of Criteria B, as defined by IEC 61000-6-2 (Generic Industrial) and EN50121-3-2 (Wayside Rail EMC)
Section 4.6
Digital Input Specifications
Specification
Isolation to System
Input 1 to Input 2 Isolation
Input Voltage
Logic High
Logic Low
Wetting Voltage
Input/Output Current
Section 4.7
Operating Environment
Parameter
Ambient Operating Temperature
Ambient Relative Humidity
Digital Input Specifications
Cable
Connector
h
Mode
Type
Type
(μm)
62.5/125
MM
LC
50/125
SM
LC
9/125
SM
LC
9/125
SM
LC
9/125
-40 to 85 °C
(-40 to 185 °F)
Tx
Tx
Tx/Rx
Minimum
Maximum
i
λ (nm)
j
(dBm)
(dBm)
850
-9
-2.5
1310
-9.5
-3
1300
-7
-3
1550
0
5
Value
1.5 kVAC
1 kVDC
+/- 30 V Maximum
+10 ~ + 30 V
-30 ~ + 8 V
+9.5 V
5-10 mA
Range
Comments
Measured from a 30 cm (12 in) radius surrounding the center of the