2. PERIODIC CHECK
2.2
Maintenance procedure of the conveyance section
2.2.1
Cleaning the conveyance section sensor
A. Periodic cleaning cycle
•
Original registration sensor (PS306): Every 500,000 prints
B. Procedure
[2]
[1]
14
1. Open the open/close cover.
2. Use a blower brush to clean the original registra-
tion sensor (PS306) [1] and the original registration
mirror [2].
15saf2c021na
Field Service Ver1.0 Jun.2005