tells the drive to start (called "Belt Forward"). Also, in the case where the belt is
allowed to run backward, another digital output is available called "Belt Reverse"
If it is desired to provide greater integration between the Genetix controller and the
Drive, the "Drive Feedback" feature may be enabled and additional inputs and
outputs will become available.
Inclinometer
An inclinometer is a device capable of sending an analog signal representing the
angle (or "inclination") of the conveyor or feeder relative to horizontal. Connected
to an analog input on a GCM, this will allow the Genetix controller to correctly
measure the belt load regardless of angle. This might be useful, for example if the
scale or feeder is installed such that this angle changes during operation.
To use this feature, it must be enabled, and the analog input must be mapped to
the "Inclination" logical analog input (see Main Menu > Advanced Setup > Analog
I/O > Inputs > Function ). Also, like all analog inputs it must be calibrated so that
the angle is correctly represented by the analog signal.

Reset Totals

Selecting this item from the Main Menu will bring up the following selections:
Reset Sub-Total...
Reset Grand-Total...
If you select "Reset Sub-Total" from the above screen you will see a screen that shows
the respective current totalizer value and asks you to confirm the reset. Press the Enter
key to reset the totalizer or press the Menu/Esc key to cancel without resetting.
If you select "Reset Grand-Total from the above menu, you will be asked for a password
to allow the reset. This is the same password as used for Calibration (default = "1234").
Upon successful entry of the password you will see a screen that shows the respective
current totalizer value and asks you to confirm the reset. Press the Enter key to reset the
totalizer or press the Menu/Esc key to cancel without resetting.

DNA Key

Selecting this item from the Main Menu will bring up the following selections: