Selecting "Warnings" from the Main Menu will present a screen that shows a list of all
Logical Inputs and Logical Outputs that have had their "Warning" property set. Next to
each input or output, you will see one of the following labels,
Label
<blank>
"Warn-Off"
"Warn-ON"
If a Logical I/O point shows the label "Warn-Off", that means that condition did occur but
is no longer present. You may scroll to that item, select it and then press the Enter key to
Reset.
If a Logical I/O point shows the label "Warn-ON", then this means the condition is still
repsent and it may not be Reset. The logical condition must no longer be present before
a Warning can be reset.
When all Warnings have been reset, the text "WARNINGS!" will disappear from the main
display.
Faults
Faults are logical conditions that may occur and which will stop the feeder. Any Logical
Input or Output can be set to trigger a Fault. To set a Logical I/O point as a Fault, see
Main Menu > Advanced Setup > Digital I/O > Warnings/Faults. Note: you should use
careful judgement in setting Faults; if they occur, they will cause the feeder to stop.
If any Fault occurs, you will see the text "FAULTS!" on the bottom of the main display,
like this:
Note: In the example shown, there are also Warnings present (see above)
Selecting "Faults" from the Main menu will present a screen that shows a list of all
Logical Inputs and Logical Outputs that have had their "Fault" property set. Next to each
input or output, you will see one of the following labels,
Page 24 of 104
Meaning
No Warning has occurred (since last
reset)
Warning occurred, but is not now
present (may be reset)
Warning occurred and is still present