Belt feeder control
with lcd user interface (105 pages)
Summary of Contents for MERRICK Genetix
Page 1
SAFETY, INSTALLATION, OPERATION AND MAINTENANCE MANUAL ® ® MERRICK Industries, Inc. 10 Arthur Drive Lynn Haven, FL 32444 +1.850.265.3611 www.merrick-inc.com...
Page 2
The information in this manual, including technical data and copies of drawings, embodies information proprietary to MERRICK Industries, Inc. and this manual is provided to the user of equipment purchased from MERRICK Industries, Inc. for use only in operation or maintenance of such equipment. Such information in this manual is not to be used, disclosed, copied, or reproduced in whole or part for any use other than that indicated above, or for any other purpose detrimental to the interests of MERRICK Industries, Inc.
Powering down the Unit.................8 Connection Menu...................8 Connect to <name>..................9 Select from list....................9 Add Feeder(s) to List..................9 Scan for Merrick Feeders ..............10 Enter Bluetooth Address...............10 Delete Feeder(s) from List................11 Sort Feeders in List ..................11 A Note about Feeder Names..............11 Charging the Batteries ..................13 Checking the Battery Voltage ................14...
The Genetix Remote Handheld User Interface is a device that allows you to completely interact with your Genetix controlled Feeder or Scale in a wireless manner. It is intended to provide you a means to temporarily control your feeder for calibration, maintenance, or diagnostic purposes in the absence of a locally mounted, wired User Interface.
The Genetix Remote Handheld User Interface is used to interface with the Merrick Genetix Core Module (“GCM”) and provide the user a means to operate the connected feeder, usually in a temporary manner. To insure personnel safety please read the following instructions and precautions carefully.
Technical Support Merrick provides customer technical and spare part support 24 hours a day, seven days a week. Our normal business hours are Monday through Friday 7:30 AM until 4:30 PM Central Time. During normal hours call 1-888 MERRICK (637-7425) and ask for service.
The wireless Remote User Interface assembly is one of many User Interface options for the Genetix controller. It functions exactly the same as the wired Genetix LCD Interface, once the Bluetooth connection is made. This Manual will explain how to connect to Merrick feeders.
When powered up, you should see the Connection Menu. This menu allows you, using the Bluetooth protocol, to find and connect to the correct Merrick Feeder and/or to manage the stored list of feeders utilizing one of the following options:...
Feeder Control manual. Note: If this menu item is not present, the Remote User Interface has never been connected to a Merrick feeder. Once this is done for the first time, it will always show the last feeder connected to.
Scan for Merrick Feeders This menu item allows you scan the immediate area for Bluetooth devices and identify the Merrick feeders. This is done with a typical Bluetooth “discovery” process and will therefore see any Bluetooth radios in the immediate area that have their visibility property turned on.
Remote User Interface. However, if the feeder name is changed, the Bluetooth name does not automatically change with it. You must cycle the power on the GCM (Genetix Core Module) that is connected to the feeder to set the Bluetooth name to be the same.
Page 12
Again from the Connection menu, select “Add Feeder(s) to List”, and then select “Scan for Merrick Feeder”. Perform the scan and you should find “NewName”. Add this feeder to the list. The list is now updated with the new feeder name. You may either connect to it now, or just leave it in the list;...
Do not attempt to charge the batteries with any charger other than the one • provided by Merrick. The batteries must be charged within the unit itself. Do not replace the batteries except with batteries supplied by Merrick. Observe •...
Merrick. Note: Do not attempt to service or repair the unit. If the unit does not appear to be operating correctly, call Merrick Technical Support for assistance. Page 14 of 15...
APPENDIX A Bluetooth Interface Card Each feeder to which you wish to connect must have its GCM (Genetix Core Module) fitted with a Bluetooth interface card, also known as the “XDC”. This is a picture of the card, which must be mounted on top of the GCM.
Need help?