Furuno DFF-3D Operator's Manual page 34

Multi beam sonar
Table of Contents

Advertisement

3. INITIAL SETTINGS
Menu item
[Motion Sensor
Set the distance from the transducer to the motion sensor
Pos. Up/Down]
in the up/down (vertical) direction. Use a "+" value for up-
ward direction.
Note: This menu appears if the motion sensor source is
selected to [SC].
[Motion Sensor
Set the distance from the transducer to the motion sensor
Pos. Port/Star-
in the port-starboard direction. For port location, set a pos-
board]
itive value.
Note: This menu appears if the motion sensor source is
selected to [SC].
[GPS Sensor
Set the distance from the transducer to the GPS sensor in
Pos. Bow/Stern]
the bow-stern direction. For stern location, set a positive
value.
[GPS Sensor
Set the distance from the transducer to the GPS sensor in
Pos. Up/Down]
the up/down (vertical) direction. Use a "+" value for upward
direction.
[GPS Sensor
Set the distance from the transducer to the GPS sensor in
Pos. Port/Star-
the port-starboard direction. For port location, set a posi-
board]
tive value.
[Roll Sensor Off-
Set the roll offset to use with the internal motion sensor.
set]
Note: This menu appears if the motion sensor source is
selected to [Internal].
[Pitch Sensor
Set the pitch offset to use with the internal motion sensor.
Offset]
Note: This menu appears if the motion sensor source is
selected to [Internal].
[Motion Sensor
Set the time lag to use with the external motion sensor.
Time Lag (in ms)]
Note: This menu appears if the motion sensor source is
selected to [SC].
[Heading Sensor
Set the time lag for the data received from the position sen-
Time Lag (in ms)]
sor.
[Position Sensor
Set the time lag for the data received from the position sen-
Time Lag (in ms)]
sor.
Sync (time lag) setting
• If the equipment is connected as shown below, no adjustment to the time lag set-
tings is necessary.
3-8
Description
Multi Function
DFF-3D
------------------
Display
Ethernet
Motion sensor time lag: 20 msec
Heading sensor time lag: 20 msec
Position sensor time lag: 20 msec
(setting range)
-100 to 100.0 (m)
-100 to 100.0 (m)
-100 to 100.0 (m)
-100 to 100.0 (m)
-100 to 100.0 (m)
-45.0 to 45.0
-45.0 to 45.0
0 to 400
0 to 3500
0 to 3500
------------
SC-30
CAN bus
Options

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents