Furuno DFF-3D Operator's Manual page 24

Multi beam sonar
Table of Contents

Advertisement

2. WIRING
9. Connect the KP cable. Pass the PH connector through the clamp shown below,
then connect it to J9 on th DIGI board. Make sure the cable does not contact the
WAGO connector (TB3). Also, secure the shield of the external KP cable to the
plate where the transducer cable is fixed.
J9
Note 1: As shown in the figure below, pass the cable through the cable saddle.
Make sure the crimp connectors are not clamped by the cable saddle.
Note 2: Confirm that the direction of the clamping plate is as shown below.
10. Attach the supplied EMI core (GRFC-10) to the cable for the external KP, approx.
10 mm from the super gland.
11. Reattach the inner and outer covers.
2-8
Lay vinyl sheath in the cable clamp and
Clamp
secure the cable with the cable clamp.
Cable saddle
Crimp
connectors
10 mm
10 mm
Make sure cable does
not contact TB3.
Shield
Clamping
plate
Super gland
Super gland
EMI core
EMI core

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents