External Kp Cable - Furuno DFF-3D Operator's Manual

Multi beam sonar
Table of Contents

Advertisement

2.3

External KP Cable

The Connector Kit for TX Sync (see the table below) and the cable MPYC(SLA)-4 are
required to connect external KP.
Name
Upset UI Screw-B
Super Gland
PH Connector Assembly
Cable Clamping Plate
Rainproof Panel
EMI Core
Crimp-on Lug
Note: FURUNO recommends use of the JIS cable MPYC(SLA)-4 (or equivalent, see
Appendix 1). However, if the wiring environment is such that the cable may contact
seawater, use a cable whose armor is covered with a vinyl sheath to prevent corro-
sion.
1. Fabricate the cable for the external KP as shown below.
a) Make the length of the wires of the PH connector assembly (supplied) 100 mm.
b) Remove the sheath from the cores 10 mm.
c) Fold back the cores in half. Attach crimp-on lug NCW-1.25 (supplied) to each
core.
(a)
(c)
Fold back core.
d) Remove the armor 300 mm and cut off the vinyl sheath 130 mm
Armor
Contents of Connector kit for TX sync
Type
M4 20
MGB20M-12B
02-1097 (4P)
02-167-1528
02-167-1529
GRFC-10
NCW-1.25
Approx. 100 mm
MPYC(SLA)-4
Vinyl sheath
Code No.
000-163-756-10
000-177-248-10
001-206-000
100-379-090-10
100-379-100-10
000-177-010-10
000-157-213-10
(b)
Approx. 10 mm
300 mm
80 mm
130 mm
2. WIRING
Qty
Remarks
2
1
1
1
1
No use. May be
discarded.
1
4
Shield
2-5