6.6 FRONT PANEL VIEW
"OFF" button: Press the OFF button to turn off the UPS and the loads.
"ON/TEST" button: With the UPS plugged in, press the ON/TEST button to turn on the
UPS and power the loads. ON/TEST button also activates the UPS's self-test function and
silences the buzzer when working at backup mode.
"BOOST AVR (VOLTAGE BOOST)" indicator (YELLOW LED): The LED illuminates
when the UPS is correcting a lower utility voltage input. The loads will continue to receive
clean power from the UPS.
"BUCK AVR (VOLTAGE REDUCTION)" indicator (YELLOW LED): The LED
illuminates when the UPS is correcting a higher utility voltage input. The loads will continue
to receive clean power from UPS.
"OVERLOAD / REPLACE BATTERY" indicator (RED LED): The LED flashes when
the loads connected to the UPS exceed the UPS's capacity. The LED will be lit steadily
when the UPS's battery is no longer useful and must be replaced.
"BACK UP" indicator (YELLOW LED): The LED illuminates when the UPS is
supplying battery power to the loads