2

Changing Assembly Parts

2.1

Tools

Do not use worn or damaged tools.
Only use tools and test devices for their designed purposes.
Specialized tools(cab in-house produced):
Test devices ribbon holders (cab part no.: 5540932)
Assembly assistance coupling (cab part no.: 5541180)
Cylindrical dynamometer (spring scale), 0 - 10 N (cab part no.: 5906108)
Commercial tools:
Torx screwdriver, size TX 10/200
Allen wrenches straight, size 2,5
Screwdriver with parallel shaft, size 4
Flat nose pliers
2.2

Changing the Control Panel

i
Note!
When changing the control panel B or P to a control panel C (exchange to measurement version) the
dispensing edge must be removed from the device. When changing the to the other panels the dispensing
edge must be mounted. ( 2.6 on page 12).
1
2
3
4
Fig. 1
Changing the control panel
1. Fold the control panel (4) down.
2. Steady the device with one hand and pull the control panel along axis (3) sturdily, releasing it from its retainer (2).
3. Take hold of the control panel over the second axis and pull it until it is released from its retainer.
4. Guide the brackets (5) next to the retainers (2) out of the device.
5. Disconnect the connector (1) from the printer and set aside the control panel.
6. Connect the connector (4) of the new control panel to the printer.
7. Guide the brackets (5) along the side of the retainers (2).
8. Lift the control panel a little.
9. Push the control panel firmly into the axis (3) of the retainer (2) until you hear the axis snap into the retainer.
7