Measuring The Breaking Force Of The Unwinder - CAB MACH 4.3S/200B Service Manual

Mach 4s series
Hide thumbs Also See for MACH 4.3S/200B:
Table of Contents

Advertisement

3
Adjustments
20
3.1.2

Measuring the Breaking Force of the Unwinder

B
3
Fig. 14
Target Value
Break of the unwinder ribbon
1. Insert the test device (3) onto a ribbon retainer (2). Note that the Spring tip must be placed in the grove of the
ribbon retainer for a true result.
2. Open the printhead assembly group and insert the ribbon retainer (2) with the inserted test device (3) onto the
rewinder.
3. To measure the breaking force wrap the string around the test device (3) as illustrated in C.
4. Connect the spring scale [10 N] (1) to the end of the string and pull it upwards vertically until the test device starts
to turn.
5. Pull until the test device complete a full revolution and measure the force F of the break.
6. If the results deviate from the target values change the settings.( 3.2 on page 21).
C
1
2
3
Measuring the breaking force of the unwinder
Measurement
Torque M
C
3,9 - 4,5 Ncm
20
Force F
1,3 - 1,5 N

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents