Restoring Default Settings Using the Reset Switch

If you are having problems with the IF2, you can press the reset switch
to restore the default settings to the IF2.
To restore defaults via a serial connection
1 Make sure the IF2 is powered on.
2 Using a paper clip, push and hold the reset switch for three
seconds. The LEDs on the IF2 flashes.
Reset switch
3 Release the reset switch. The IF2 reboots and restores the default
configuration.

Restoring Default Settings Using a Serial Connection

If you are having problems with the IF2, you can use a serial
connection to restore the default settings to the IF2.
To restore defaults via a serial connection
1 Open a serial connection to the IF2. For help, see
Serial or USB Connection to the IF2" on page 54.
2 In the login field, type restore_defaults and then press
Enter.
3 In the Password field, press Enter. The IF2 reboots and the default
settings are restored.