DA-IRIGB-4DIO-PCI104-EMC4 Module
Function ID
12
13
16
17
18
NOTE
Function IDs 8, 9, 14, and 15 are not available for the DA-IRGB-4DIO-PCI-104-EMC4 module, which does not
support the fiber input port.
For example, if you want to set the IRIG-B RTC time to 2014/01/01 03:25:00, enter the following command.
mxIrigUtil -f 2 -p 2014,1,1,3,25,0
Function description
Display input signal type.
Set input signal type.
Display digital output.
Set digital output.
Display digital input.
Software Installation and Configuration
Parameters
port [0|1]
Where
1 is port 1 input.
port, signal type, mode, inverse
Where
port – 1 is "Port 1"
signal type – 0 is TTL; 1 is "DIFF"
inverse – 0 means do not inverse; 1 means
inverse.
port
where 0 is "DO0", 1 is "DO1", 2 is "DO2",
and 3 is "DO3"
port, level
Where
port – 0 is "DO0", 1 is "DO1", 2 is "DO2",
and 3 is "DO3"
level – 0 is low and 1 is high
port
Where 0 is "DI0", 1 is "DI1", and 2 is "DI2"