RLX2 Industrial Hotspot Series
Size
Shock
Vibration
Ethernet Ports
Antenna Port
Weight
Environmental
Operating Temperature
Humidity
External Power
PoE Injector
Power over Ethernet
Average Power Consumption
Agency Approvals & Certifications
Wireless Approvals
Visit www.prosoft-technology.com for current wireless approval information.
Hazardous Locations
UL/cUL; Class1, Div 2
Ex Certificate (ATEX Directive, Zone 2)
RLX2-IHNF, -W, -WC Detailed Specifications
Radio
Frequency Band
(Varies by country)
Page 176 of 212
14.8 x 11.8 x 3.8 cm (H x W x D)
5.82 x 4.64 x 1.48 in (H x W x D)
IEC 60068 2-6 (20 g, 3-Axis)
IEC 60068 2-27 (5 g, 10 Hz to 150 Hz)
One 10/100/1000 Base-T connector, shielded RJ45
(1) RP-SMA connector
1.1 lbs (499g)
-40°C to +75°C (-40°F to +167°F)
Up to 100% RH, with no condensation
10 Vdc to 24 Vdc
48 Vdc
802.3af Compliant
Less than 7 Watts
Regulatory
CSA/CB Safety
CE Mark
FCC/IC
ETSI
Frequency
2.412 GHz to 2.462 GHz (FCC)
2.412 GHz to 2.472 GHz (ETSI)
5.150 GHz to 5.250 GHz (FCC/ETSI)
5.250 GHz to 5.350 GHz (FCC/ETSI)
5.470 GHz to 5.725 GHz (FCC/ETSI)
5.725 GHz to 5.850 GHz (FCC)
*DFS channels with RADAR detection
Channel
1 to 11
1 to 13
36, 40, 44, 48
52, 56, 60, 64
100, 104, 108, 112,
116*, 132, 136,
140*
149, 153, 157, 161,
165