Risk of Injury Due to Sharp Edges and Protruding Parts

Danger!
There may be a risk of injury due to protruding parts.
Protective goggles should be worn.
There may be a risk of injury due to sharp edges. Protective gloves should
be worn and the edge protection (mat. no. 05057680) should be used.
4

Uninstalling the Dishwasher

Before the machine is removed from its installation niche, the appliance
feet must be screwed in (for positioning, refer to the installation plan).
If this is not done the feet could become damaged.
If the machine is installed on skids, adjusting the feet is not required.
5
Service Work – Casing
Warning!
If it is necessary to tip the machine when working on its lower areas, it
may only be tilted onto its back.
The appliance must not be tilted onto its left side as this would cause
brine to run out of the salt container.
After work has been completed and the machine installed again, a short
program without load should be carried out. This is to remove any salt
residues that might be present and to prevent possible corrosion.
6

Installation Aids Containing Silicone

Warning!
Installation aids that contain silicone, e.g., silicone grease, are not suitable for
use in dishwashers because of the damage they can cause.
If, e.g., hoses or seals are treated with silicone in order to facilitate
installation, this could jam the circulation pump. Furthermore, ingredients in
silicone grease can evaporate and damage electrical components such as
heater relays.