Fault Code F13: Water Intake Fault At End Of Step - Miele G 4205 Technical Information

G 5 series futura dishwashers
Hide thumbs Also See for G 4205:
Table of Contents

Advertisement

G 5xxx
housing.
2. Select and start a wash program.
3. After the drain step (30 seconds), the water inlet step will begin. Wrap
one hand around the valve housing. If there is a mild vibration, then the
valve is receiving power. Replace the WPS valve (Section 050-4.27). If
not, then go to the next step.
4. Remove the drip pan (Section 010-4.2) and check the electrical connector
to the inlet valves (mounted on the left toekick) for power. If power is
present, then check the connectors and wiring. If not, then go to the next
step.
5. Check for power coming off of the electronic board. If no power, then
replace the electronic board. If power is present, check wiring from
electronic board to electrical connector. Replace and repair as necessary.
3.13

Fault Code F13: Water Intake Fault at End of Step

Symptom:
The program is interrupted and the drain pump is operated. After
approximately 2 to 4 minutes, the buzzer is activated for 2 minutes.
Background information:
This fault is registered when the desired number of pulses, which varies
depending on program, has not been detected within a certain given time
(maximum 4 minutes).
If the selected program starts with a water softener flushing cycle, the fault
code register check is carried out earlier. In the event of a fault, the selected
program is interrupted after approximately 30 seconds and the fault is
indicated.
Cause:
On-site water supply not in order (water pressure below 14.5 pounds per
square inch).
Remedy:
The on-site water supply should be checked by a specialist.
Cause:
Water inlet valve defective.
Remedy:
Check the water inlet valve and replace it if necessary (Section 050-4.27).
Cause:
Flow meter B3/4 is providing too few pulses.
Remedy:
1. Check WPS valve Y63 (filter, restrictor disc).
2. Remove the left side panel (Section 010-4.1).
3. Check that the plate with the reed switch on flow meter B3/4 is seated
correctly.
4. Check that the reed switch connection plug is seated correctly.
5. Replace the reed switch, if necessary (Section 050-4.7).
131