pulsed operation for 60 seconds. The pulse rhythm throughout the test
period is 10 seconds on/10 seconds off.
11. Y38, Y5, ... Reactivation sequence (mini-program): This starts with 30
seconds drainage which begins with pulsed priming (2 seconds on/2
seconds off). The water inlet valve with EGS valve is then activated until
8.3 fluid ounces (250 milliliters) has been reached or 60 seconds has
elapsed. The reactivation valve is then activated for 150 seconds.
Following this the water inlet valve and the drain pump, which begins with
pulsed priming (2 seconds on/2 seconds off), are operated together for 60
seconds.
12. Y5, EGS valve. The EGS valve is activated for 60 seconds.
13. Y38, reactivation valve: The reactivation valve is activated for 60
seconds.
14. M2, fan: The fan is activated for 60 seconds.
15. M6, circulation pump: The circulation pump is activated for 30 seconds at
maximum speed. If the desired speed has not been reached within 7
seconds, the circulation pump will remain stationary. (MPEW only.)
Warning!
The circulation pump must not run for more than 30 seconds without water.
16. 2B3-20, M6, wash sequence with middle spray arm sensor (mini-program): This
starts with 30 seconds of drainage which begins with pulsed priming (2 seconds
on/2 seconds off). The water inlet valve is then activated (on models with and
without slide shutter) until 1.4 gallons (5.4 liters) has been taken in. At the same
time the water inlet valve is activated, the slide shutter is set to the middle spray
arm position. The circulation pump with switched auxiliary winding is then
operated. If a spray arm fault is registered during circulation pump operation, the
pump is switched off after 60 seconds; otherwise, it operates for a further 120
seconds. (Models with spray-arm sensing only.)
17. 1B3-20, M6, wash sequence with bottom spray arm sensor (mini-program):
This starts with 30 seconds of drainage which begins with pulsed priming
(2 seconds on/2 seconds off). The water inlet valve is then activated (on
models with and without slide shutter) until 1.4 gallons (5.4 liters) has
been taken in. At the same time the water inlet valve is activated, the
slide shutter is set to the middle spray arm position. The circulation pump
with switched auxiliary winding is then operated. If a spray arm fault is
registered during circulation pump operation, the pump is switched off
after 60 seconds; otherwise, it operates for a further 120 seconds.
(Models with spray-arm sensing only.)
18. A2, Drying Plus (automatic door lock latch): In the home position, door
contact switch S24 must be closed. After the component test begins, the
latch extends until it reaches position 3 (drying position), while the door
lock remains locked. Then, door contact switch S24 must be opened, and
the latch moves to position 2 (door open). The door must be closed, and
117