Technical Information

Figure 050-21: Combination Filter

Note:
If the filter combination is already held together with a locking piece, this
must be broken open and removed.
4.24

Filter Combination Assembly (New Microfine Filter and Handle)

Note:
During assembly, the dishwasher is used as a guide.
If a new microfine filter and handle (crown coarse filter) are used, a locking
piece is not required.
1. Disconnect the appliance from the power supply.
2. Place the microfine filter in the sump. Ensure that the lug is positioned
towards the rear of the machine.
3. Turn the microfine filter clockwise as far as possible; see Figure 050-22.
4. Install the large surface area fine filter.