Hitachi G200 Hardware Reference Manual page 114

Virtual storage platform
Hide thumbs Also See for G200:
Table of Contents

Advertisement

Impact
Angle at which the storage system turns
over
Altitude
Atmosphere
Acoustic Noise
114
Item
Operating (m/s2)
Non-operating (m/s2)
Transport (packed)
(m/s2)
Operating (m)
Operating
Standby
Environmental specifications for VSP G200
Hitachi Virtual Storage Platform G200 Hardware Reference Guide
CBSSD/CBSLD/
DBSD/DBLD
20 or less
50 or less
80 or less
15° or less
To be measured when installed
-60 to 1,800 above
sea level
Environmental
temperature: 41°F to
104°F (5°C to 40°C)
-1,800 to 4,000
above sea level
Environmental
temperature: 41°F to
86°F (5°C to 30°C)
No corrosive gas and
salty air must be
found.
60 dB
meter away from the storage
Environmental
temperature: 89.6°F
(32°C) or less
The system's internal
temperature controls
the rotating speed of
the fan. Therefore,
this standard value
might be exceeded if
the maximum load
continues under high-
temperature
environment or if a
system failure occurs.
55 dB
Notes
10 ms, half sine wave
on leveling bolts.
Measured at the position 1.5
system, at a height of 1.5
meters.