3.3.4) Thread stand installation
- Install thread stand on a table.
While attaching using tools, be careful not to drop one of the parts and get injured.
CAUTION
3.3.5) Installation of pneumatic controlling parts
1) Filter regulator
Install a filter regulator at the bottom of a table support with a bolt.
When connecting an air hose, use a quick joint socket to link it to the quick joint plug attached on a regulator.
2) Solenoid valve
Fix a solenoid valve to a table support with a set bolt.
1) Adjust proper pneumatic pressure to 5~5.5kgf/cm (0.49~0.54MPa).
2) When the pressure drops less than 4kdf/cm, machine stops operating with an error
3) When you turn off the finger valve after use, residual air is automatically emitted and
CAUTION
14
Hose
Quick joint socket
message. (Error message: Err 24 (Low Pressure!)