System Wiring Diagram - First Alert FA848C Installation And Setup Manual

Hide thumbs Also See for FA848C:
Table of Contents

Advertisement

• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •

System Wiring Diagram

_
BLACK
ANTENNA 1
+
RED
12V, 4-6H
BATTERY
MODEL 467
JP4 JUMPER
PINS
APPLICATION
STANDARD BELL
1 & 2
SUPERVISION
2 & 3
EXTERNAL SIREN
DRIVER SUPERVISION
(USE TERM. 6 FOR
SVSN. INPUT)
TRANSFORMER
16.5 VAC, 40VA
(CONNECT TO 24 HR.
120VAC, 60Hz
OUTLET)
SELF-CONTAINED
SIREN
IMPORTANT: All control panel wiring should be completed prior to applying power to avoid possible
harm to circuits due to electrostatic discharge.
SYSTEM STABILIZATION MODE: Upon power-up of the system and after completion of system
programming, all the lights on the LED keypads flash momentarily and the LCD keypads display
"STANDBY!" HOWEVER, THE ZONES WILL NOT RESPOND TO ALARM CONDITIONS FOR
APPROXIMATELY 2 MINUTES. The 2-minute interval is used to allow motion detectors (interior zones)
to stabilize on power-up in order to prevent false alarms. The 2-minute response time can be disabled by
simply entering a valid user code, which disarms the system and reduces the power-up reset time to
approximately 5 seconds.
NOTE: If total system power is lost, then upon power restoral, the system returns to the previously
armed state.
6\VWHP:LULQJDQG+RRNXS
CONNECT GROUNDING LUGS TO LEFT-HAND TERMINALS
HARDWIRE ZONE EXPANDER
P2
29 30 31 32 33 34 35 36
2.2k
2.2k
2.2k
ZONE
ZONE
ZONE
BELL SUPV
9
10
JP4
EXT. SIREN SUPERVISION INPUT
1
2
3
4
5
6
7
8
9
10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28
-
+
+
AUX PWR
(500mA MAX)
FIRE &
2.2k
2.2k
2.2k
BURGLARY
ALARM
ZONE
ZONE
ZONE
OUTPUT
1
2
3
(11.5 -
13.1VDC,
1A MAX)
TYPICAL CONNECTION
FOR ZONE DOUBLING
BELL
OR
9
10
ZONE 1
3.3k
+
ZONE 2
-
7.5k
DIRECT PLUG-IN
(Wireless Zones)
JP1
JP2
PROGRAMMING
DEFAULT JUMPERS
OMNIEXP 8
(optional)
P3
37 38 39 40
2.2k
2.2k
2.2k
2.2k
2.2k
ZONE
ZONE
ZONE
ZONE
ZONE
11
12
13
14
15
16
SMOKE POWER (6+) & (7-)
12VDC REG., 50mA MAX
2.2k
2.2k
2.2k
2.2k
2.2k
ZONE
ZONE
ZONE
ZONE
ZONE
4
5
6
7
8
STANDARD EOLR
TYPICAL DOUBLE
BALANCED ZONES
9
10
11
TAMPER
USE WITH
2.2k
2.2k
CONTACTS
FALCDKP
FALEDKP
TAMPER
2.2k
2.2k
CONTACTS
2.2k
2.2k
S E C T I O N
P3
ANTENNA 2
P2
ZR401
RF RECEIVER
(optional)
TRIGGERS
TRIGGERS
WARNING
TO PREVENT RISK FROM ELECTRICAL
SHOCK, DE-ENERGIZE THE SYSTEM
CONTROL UNIT AND DISCONNECT THE
TELEPHONE LINES BEFORE SERVICING
THIS UNIT.
MODEL 368 CORD
TO RJ31X OR
CA38A JACK
HOME
TELCO
GROUND LUG
2
RECEIVER
INTERNAL
CONNECTIONS
OPTIONAL
TRIGGER CABLE
XL4612TC
+VBELL
TRIGGER 1
*
TRIGGER 4 (OR DATA)
*
TRIGGER 3 (OR CLOCK)
TRIGGER 2
GROUND
*
IF XL4705 RELAY
MODULES USED.
TELCO CONNECTOR
(APPLICABLE ONLY
IN AUSTRALIA)
FA848C-001-V0