Stay Arms Stay: If enabled, the system will arm in the STAY mode by simply pressing the
STAY key (user code not required). Otherwise, the user must press the STAY key followed
by the user code to arm in STAY mode.
No Fob Auto-Stay: If selected, the auto-stay feature will be disabled when arming from a
keyfob (system will arm the system in the mode selected).
Instant Arms Away: If enabled, the system will be armed in the AWAY mode by pressing
the INSTANT key.
Instant Enabled: If selected, allows the end user to arm instant mode. Not available if
INSTANT ARMS AWAY selected.
Q 19, L2
Enter the L2 digit from the table below.
L2
Entry
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
Arm with Fault: Allows the system to arm even if a delay or interior zone is faulted.
However, faulted zones must be restored before exit time expires or an alarm will result.
Bypass Error/Exit Error: If bypass error is selected, faulted delay or interior zones will be
automatically bypassed when exit time expires (no exit error report will be sent). If exit
error is selected, faulted zones remain faulted, but and exit error report will be sent.
No PC if Armed: If any partition is armed, the control will not communicate with
downloading computer.
No Arm if Low Battery: If selected, no partition will arm if a system low battery exists.
Q 19, L3
Enter the L3 digit from the table below.
L3
Entry
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
6-16
Arm with
Bypass
Fault
Error
Disable Arm
Disable Arm
Part. 1
Part. 2
No PC if
Exit Error
Armed
Disable Arm
Exit Extends
Part. 3
No Arm if Low
Battery
Need help?
Do you have a question about the FA848C and is the answer not in the manual?
Questions and answers