TO ENTER PROGRAMMING MODE: Local programming requires the use of an alpha keypad connected to the keypad terminals on the control. 1. POWER UP, then depress [ ] and [#] both at once, within 50 seconds of powering up. 2. Initially, key: Installer Code (default = 4112) plus 8 + 0 + 0. (if 98 was used to exit previously, see To Exit Programming Mode paragraph below.
Page 3
352*5$00,1*)250 Entry of a number other than one specified will give unpredictable results. Values shown in brackets are factory defaults. Entries shown in dashed boxes indicate partition entries for FA168C only (not applicable for FA148CP). Field Function Data Entries Programmable Values SYSTEM SETUP ( 20–...
Page 4
NOTE: Entry of a number other than one specified will give unpredictable results. For fields *43-*46: Enter 0–9; #+11 for B; #+12 for C; #+13 for D; #+14 for E; #+15 for F. Enter [ ] as the fourth digit if a 3-digit account number (for 3+1 dialer reporting format) is used.
RF XMTR LOW BAT REPORT CODE [00] See box on previous page. UL: must be enabled if wireless devices are used CANCEL REPORT CODE [00] See box on previous page. RESTORE REPORT CODES ( 70 – 76) ALARM RESTORE RPT CODE See box on previous page.
Page 6
DOWNLOAD INFORMATION ( 94, 95) DOWNLOAD PHONE No. Enter up to 20 digits, 0–9; #+11 for ' '; #+12 for '#'; #+13 for a 2-second pause. Do not fill unused spaces. If fewer than 20 digits, exit field by pressing (and press 95, if entering next field).
Page 7
FA148CP: 1 = enable beeps 0 = disable See field ∗190 for entries. 191 KEYPAD 3 ADDRESS 18 [0] [0] † FA168C: enter partition † Part./Enable Sound FA148CP: 1 = enable; 0 = disable See field ∗190 for entries. 192 KEYPAD 4 ADDRESS 19 [0] [0] †...
Page 8
Configurable Zone Types Worksheets Configurable zone types 90 and 91 can be programmed via downloader software or from a keypad using data fields*182-*185. Configurable zone types 92 and 93 (FA168C only) can only be programmed using the downloader software. Programming Configurable Zone Type options involves making 10 entries in data field *182 for zone type 90 and field *184 for zone type 91, where each entry represents the sum of the values of the various options shown in the tables below.
Page 9
*56 ZONE PROGRAMMING WORKSHEET (FA148CP supports up to 32 zones: 1-6, 9-34) [default shown in brackets] Zone Zn Type Part. Report Input Type Loop Rsp. Time Serial No. Location [09] [HW] [01] [HW] [03] [HW] [03] [HW] [03] [HW] [03] [HW] [03] [HW]...
Page 10
OUTPUT RELAYS/POWERLINE CARRIER DEVICES WORKSHEET FOR ∗79, ∗ 80 and ∗ 81. Applicable only if Relays and/or Powerline Carrier Devices are to be used. ∗79 RELAY/POWERLINE CARRIER DEVICE MAPPING (Must program before using *80) OUTPUT TYPE OUTPUT TYPE (09-16 apply to FA168C only) Relay Relay Output...
Zone Type Definitions Use this zone type if the zone is not used. Type 00 Zone Not Used • Assign to zones that are used for primary entry and exit. Type 01 • Provides entry delay if the control is armed in the Away or Stay modes. Entry/Exit Burglary #1 •...
Page 13
*The system can still be armed when these zone types are in a faulted condition. Schedules (installer code + [#] + [6] [4]; master code can only access schedules 01-16 for FA168C, 01-04 for FA148CP, and events 00-07 for both controls; FA148CP supports up to 8 schedules, FA168C supports up to 32 schedules ) Event Device No.
ALPHA VOCABULARY LIST (For Entering Zone Descriptors) (Word Space) • 057 DOOR – L – – R – – V – • 106 LAUNDRY RADIO VALVE • 059 DOWN – A – VAULT • 107 LEFT • 060 DOWNSTAIRS • 156 REAR •...
8 5800TM Module automatic † These module addresses apply to FA168C only. †† Addressable devices are identified by “1” plus the device address when reporting. Enter report code for zone 91 to enable addressable device reporting (default = reports enabled). See field *199 for addressable device (ECP) 3-digit/2-digit identification touchpad display options.