One of the three modes of operation, Manual, LRR Line Card and 685 Automation must be
selected during the 7810iR programming.
Manual Mode
U L
Manual Mode and Fail to Manual Mode cannot be used with UL installations.
Manual Mode is a standalone method of receiving contact ID messages from a protected
premises. Incoming messages are displayed in ADEMCO high-speed or Contact ID format in
the New Alarm Window of the 7810iR. An operator is required to silence an incoming alarm
and manually move it from the New Alarm window to the Alarm History window using the
GUI.
Both the New Alarm window and the Alarm History window are first-in first-out (FIFO)
buffers that are limited to a total of 100 entries. Once 100 messages have been received in
the New Alarm buffer, the next message received will push the oldest alarm off the list.
There is no method to save or archive messages in these buffers when the 7810iR is being
used in the Manual Mode.

Alarm Sequence in Manual Mode

1. Manual Mode "Home" screen.
o
685 Automation Mode
o
ADEMCO High-Speed Message Format
Action
S E C T I O N
Operation
Screen Display
5
5-1