Contact Id Format; Event Code Classifications - Honeywell AlarmNet 7810iR Installation And Setup Gude

Internet communication module
Hide thumbs

Advertisement

Contact ID Format

Contact ID reporting takes the following format:
Where:
CCCC = customer (subscriber account number)
Q = event qualifier, E = new event, R = restore
EEE = event code
GG = partition number, 00-08 (always 00 for non-partitioned panels)
ZZZ = zone ID number reporting the alarm (001-099), or user number for open/close reports.
* System status messages (i.e. AC Loss, Low Battery) contain zeros in the ZZZ location.
SUBSCRIBER ID #

Event Code Classifications

Medical
100
101
102
Fire Alarms
110
111
112
113
114
115
116
117
118
Panic Alarms
120
121
122
123
124
CCCC Q EEE GG ZZZ
EVENT
QUALIFIER
Event or
XXXX
Restore
E or R
Medical
Pendant Transmitter
Fail to report in
Fire
Smoke w/Verification
Combustion
Waterflow
Heat
Pull Station
Duct
Flame
Near Alarm
Panic Alarm
Duress
Silent
Audible
Duress-Access Granted
EVENT CODE*
PARTITION #
000
Emerg-Personal Emergency-#
Emerg-Personal Emergency-#
Emerg-Fail to check in-#
Fire-Fire Alarm-#
Fire-Fire Alarm-#
Fire-Combustion-#
Fire-Water Flow -#
Fire-Heat Sensor-#
Fire-Pull Station-#
Fire-Duct Sensor-#
Fire-Flame Sensor-#
Fire-Near Alarm -#
Panic-Panic-#
Panic-Duress- User 000, or duress zone number on
low end panels
Panic-Silent Panic-#
Panic-Audible Panic-#
Panic-Duress Access Grant-#
Section 6: Message Formats
ZONE OR
USER #
C000 or U000
00
6-13