Technical Data
Cables
This section provides information about the cables that are used with IP Office.
Refer to page 63 for port pin out details.
All of the following cables are for internal use only.
All structured cabling/site wiring must conform to all local regulations.
Cautions:
DTE Cable
SAP Code.:- 700213432 (25 Way)
A 25 Way (or 9 Way on IP412) D-Type Plug with UNC 4-40 locking screws.
B 9 Way D-Type Socket with UNC 4-40 locking screws.
C 12 core screened cable - each core is 7/0.203mm (24 AWG) tinned copper stranded
wire, nominal capacitance of 95pF/m, resistance of 92 Ω/km, screened with tinned
copper braid, maximum working voltage of 440V rms and a Maximum current per core
of 1A rms
D 2 meters/6.57ft.
Pin Connections
End A (25 Way)
2
3
4
5
6
7
8
20
22
IP Office Installation Manual
40DHB0002USCL – Issue 9 (28th October 2003)
1.
All ISDN and WAN cables should not be longer than 5 meters in length.
2.
For Analog Trunk cables, to reduce the risk of fire, use only No. 26 AWG
or larger telecommunications line cord.
A
End A (9 Way) Name
3
2
7
8
6
5
1
4
9
C
D
Receive data
Transmit Data
RTS (Request To Send)
CTS (Clear To Send)
DSR (Data Set Ready)
Ground
DCD (Data Carrier Detect)
DTR (Data Terminal Ready)
RI (Ring Indicator)
Cables - Page 67
B
End B
3
2
7
8
6
5
1
4
9
Technical Data - Page 67
Cables