4.3.
Materials
In this window, material properties can be programmed. You can edit existing materials,
program new materials or delete existing materials. A maximum of 6 materials can be
programmed on the control.
For each material, three properties are present and can be viewed and edited.
Material name. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..NA
Name of the material. The maximum allowed length of the material name is 25
characters, the name must begin with a character (not a numeral).
Tensile strength . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..S
Tensile stength of the selected material.
E module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..E
E- module of the selected material.
The materials are initially listed according to their material number, which is shown in the first
column (ID).
To change an existing material, go to the relevant line and change the values as you see fit.
Use the ENTER key to confirm a typed value.
To delete an existing material, move the cursor to the relevant line and press the function key
'delete material' (S6) to erase the values.
To program a new material, move the cursor to an empty space and start programming its
values.