Homelogix™ Hlx-40 Software Manual - Rosslare HomeLogix HLX-40 User Manual

Advanced wireless security panel
Hide thumbs Also See for HomeLogix HLX-40:
Table of Contents

Advertisement

Editing a Panel Account
Section
Property
Item
Sirens Mode
Wired Siren Relay
Polarity
Internal Siren
Wired Siren
General
Supervision Time
Security
(Hours)
Settings
Jamming
Detection
No Activity Timer
(Minutes)
Trouble Beeps
Bypass Option
Quick Arm
Panic Button
Duress Code
Alarm Cancel
Time (Minutes)
Alarm Abort Time
(Seconds)
Backlight Time
32
Description
The sirens are activated if the specified arming
mode is set. The options are: Away and Away +
Home.
The polarity of the wired siren. The options are:
N.O. (Normally Opened) and N.C. (Normally Closed).
The status of the internal siren. The options are:
Enabled and Disabled.
The status of the wired siren. The options are:
Enabled and Disabled.
If this number of hours elapsed and HR-P02 did not
receive any message from a zone, a zone trouble
event is triggered. The options are: 1, 2, 4, 6, 8, 16,
24, and 48.
Defines the method used to detect attempts to jam
the RF signals from their enrolled detectors. The
options are: Disabled, UL Enabled, and EN Enabled.
If the timer is enabled and there is no activity for the
specified number of hours for any of the zones
where no activity check is enabled, a trouble event
is reported. The options are: Disabled, 1, 2, 5, 10,
15, and 30.
The options are: Disabled (default), Day only, Day
and night.
The method of setting a zone as bypassed. The
options are: Off, Off/Force, Manual, and Manual
Force.
If enabled, HR-P02 can be armed without entering a
user code. The options are: Enabled and Disabled
(default).
If enabled, pressing the panic button is reported
(with a chime if the Audible value is selected). The
options are: Disabled, Audible, and Silent.
The duress (forced disarm) code - four decimal
digits.
During this time frame (0-60 minutes), after an
alarm starts, a disarm results in the sending of an
Alarm Cancelled message to the Central Station.
If an alarm is triggered, the alarm message to the
Central Station is delayed for this number of
seconds (0-60) to allow the user to abort it via
disarm. This is effective only for burglar type of
zones.
Time that the backlight remains on. The options are:
Always and 15 seconds.