5.3.2.1 Positioning the vacuum base plate

1. Mark the center of the hole to be drilled with a cross. The lines of the cross should be longer than the
diameter of the water collector.
Note
The water collector has four protruding marks that can be aligned with the cross.
2. Turn the 4 leveling screws on the vacuum base plate until they project approx. 5 mm below the underside
of the vacuum base plate.
3. Position the vacuum base plate at a distance of 21 cm from the hole center.
4. Connect the vacuum connector on the vacuum base plate to the vacuum pump.
5. Switch on the vacuum pump.
6. Keep the vacuum release valve pressed in while correcting the position of the vacuum base plate.

5.3.2.2 Fastening the drill stand on the vacuum base plate

1. Switch on the vacuum pump.
2. Use the clamping spindle to fasten the drill stand on the vacuum base plate.
3. Level the drill stand by turning the two leveling screws.

5.3.3 Mounting the machine on the drill stand

Note
If vacuum fastening is used, check to ensure that the drill stand is securely fastened to the working
surface before mounting the machine on the drill stand.