Fastening The Machine And Drill Stand With The Vacuum Base Plate - Hilti DD 30-W Manual

Hide thumbs Also See for DD 30-W:
Table of Contents

Advertisement

WARNING
Water running out presents a risk of electric shock! The spray guard cannot be used when the
machine is mounted on the drill stand. The machine is therefore not protected against entry of water
when mounted on the drill stand.
▶ Never drill in an upwards direction with the machine mounted on the drill stand!
Note
The side handle and spray guard (if fitted) must be removed before using the machine on the drill stand.
5.3.1 Fitting the water collector holder
Note
Drilling is permissible only under the following conditions:
The supplied water collector holder is fitted and adjusted to match the length of the core bit used.
A core bit sealing ring that matches the diameter of the core bit must be fitted in the water collector
holder.
1. Unplug the supply cord from the power outlet.
2. Push the water collector holder into the opening provided at the front of the machine until it engages with
a click.
3. Use the slider to set the correct length range for the core bit used. Set the slider to the 150 position for
core bits with a length of up to 150 mm and set it to 300 for core bits with a length of 300 mm or 600 mm.

5.3.2 Fastening the machine and drill stand with the vacuum base plate

WARNING
Risk of injury Hazard presented by a falling diamond core drilling machine.
▶ When drilling horizontally, the drill stand must be secured additionally by a chain.
Printed: 06.07.2017 | Doc-Nr: PUB / 5283534 / 000 / 05